CASE STUDIES:

Warehouse Woes in Marietta

case study arrow right

The Challenge AquaGuard Foundation Solutions were approached by a Commercial Company to assist them with resolving concerns in their Warehouse. The company moved into the warehouse premises in January 2016, and after 6 months of being in the building, they started noticing cracks on the interior block walls, a sizable crack in the concrete floor plus there were a myriad of small cracks in the dry-wall. They watched the problem cracks get bigger over a two-year period, hoping that it was going to stop.  The AquaGuard Team conducted a diagnosis knowing that the symptoms all pointed towards a foundation issue. It was quickly determined that the left side of the building had sunk about 5 inches over a period-of-time. In…

CASE STUDIES:

Bill Carruth Parkway Bridge over Norfolk Southern Railroad, Paulding County, GA

case study arrow right

The Challenge When one of Georgia’s 159 counties is looking for a concrete leveling fix AquaGuard’s Commercial and Government Division has the solution.  Most recently, Paulding County was experiencing a problem with slab settlement at a bridge approach.  This bridge was opened to traffic in February of 2014, and since then, slab settlement has occurred for a variety of reasons. This section of road is extremely busy, with 4 lanes bearing the daily traffic weight of more than 13,000 vehicles. The county has measured, that over a 24-hour period, approximately 5% of this traffic is semi-truck traffic.  In this case, slab settlement has no doubt occurred due to a combination of poor compaction during construction, load limits being regularly exceeded,…

CASE STUDIES:

Back-Yard Sink-Hole Repair for the City of Newnan

case study arrow right

The Problem The City of Newnan contacted us to examine a sink hole in a resident’s back yard. On investigation we discovered that the buried 48-inch corrugated metal pipe was bent, causing several of the Pipe’s joints to separate. This separation allowed support soil from below, around and above to flow into the pipe causing the sink hole to grow. As it grew, it affected the neighbor’s yard as well. With such a massive loss of support soil, the pipe continued to move, the separation of pipe joints worsened, and we saw how the earth opened to form this dangerous sink hole. 

CASE STUDIES:

Installing A TripleSafe Sump Pump In Atlanta

case study arrow right

As water leakage began seeping in from the cinderblock walls of our client’s unfinished basement, it began to cause not only a foul smell, but also created a lack of usable space. Additionally, the presence of moisture created the atmosphere for mold and mildew growth, as well as wood rot and the potential for structural damage, which could cause a variety of health problems – both for our clients and their home. The home was built on a sloping elevation in such a way that water naturally pooled around the basement foundation, and the resulting water influx prompted our client to call AquaGuard and have one of our system design specialists come out to assess the situation.  